Pulse Discharge
The graph titled ODYSSEY® pulse discharge per battery shown below demonstrates the extraordinary short duration (pulse) discharge capabilities of the ODYSSEY® family of batteries. Note that the discharge figures are shown for an ambient temperature of 25°C and to an end of discharge voltage (EODV) of 7.20V per 12V battery.
ODYSSEY®
pulse discharge per battery

Two points should be kept in mind when using this battery for such extreme high-rate discharges. First, sufficient time must be given between two successive discharges to allow the terminals to cool down. Second, the graph reflects the capabilities of fully charged ODYSSEY® batteries. Unless the batteries are fully charged, one must not expect them to meet these numbers. Finally, all of these numbers are for an ambient temperature of 25°C; if the temperature is significantly different from 25°C, the graph shown above must be appropriately modified.
Table I below provides the five, ten and twenty second pulse discharge numbers for the ODYSSEY® line of Drycell™ batteries.
| Battery | Pulse discharge in amps to 7.2V | ||
5 sec. |
10 sec. |
20 sec. |
|
PC545 |
545 |
495 |
420 |
PC680 |
680 |
595 |
525 |
PC625 |
625 |
545 |
480 |
PC925 |
925 |
870 |
765 |
PC1200 |
1200 |
1090 |
900 |
PC1700 |
1700 |
1540 |
1355 |